Vertical 34 copper clad ground rod to 28505 lightning protection conductor horiztonal thru top. See specific nvent erico cadweld mold requirements part number l160 price key c e q r mold size 3 standard packaging quantity 1 pc upc 78285630375 warning. Forms a permanent, low resistance connection provides a molecular bond erico cadweld exothermic connections are rated with the same current capacity as the conductor. Erico cadweld one shot wire to ground rod clamps gt1. Application exothermic connection systems are used to form permanent, low resistance.
The cadweld exothermic process fuses the ccs conductors together to form a connection that will not corrode, loosen, or increase in resistance for the intended service life of the installation. Cadweld molds wire to vertical flat steel down vertical cable to vertical flat steel mold. Estimate system resistance values for basic grounding system designs and calculate the number of bags of ground enhancement material required with our gem calculator. Grounding standoff for telecom towers busbars grounding busbars and supports provides a direct, lowimpedance electrical ground connection to the tower. See specific erico nonexplosive erico cadweld welding. Cable to steel vsc1v erico cadweld graphite molds are designed and engineered for thousands of connection styles and conductor combinations.
Cadweld welded electrical connections europe 22509 1. All other trademarks are the property of their respective owners. Please keep image files under 1mb in size and pdf files under 5mb in size. Cadweld plus control unit initiates the reaction of the metal crucible. The lead attaches to the ignition strip using a custom made, purposedesigned termination clip. No need for disks, starting materials, igniters etc. Cadweld connections quickly, easily and inexpensively. Cadweld electrical welding materials are exothermic mixtures that react to produce molten metal and a ceramic phase byproduct. See specific nvent erico cadweld mold requirements. Weld metal, disk and ignition source are located inside package.
Use of improper or damaged equipment can lead to exposure to molten metal and reaction byproducts, resulting in p ersonal injury. This specification covers the cadweld exothermic welding system for use in making. Cadweld adapter sleeves cadweld adapter sleeves are used to adapt a limited range of smaller size cables to a larger size. Handle clamp l160 used to securely close the mold around the conductors. Cadweld plus was developed as a simplified method of performing exothermically welded electrical connections. The typical cadweld system requires a graphite mold, handle clamp, welding material, natural bristle brush for mold cleaning, wire brush for cleaningpreparing. Cadweld welded electrical conections linkedin slideshare. Erico cadweld plus weld metal, electronic igniter site pro 1.
N cadweld starting material not sold separately page 27 components chemical component chemical symbol cas number einecs number eu risk phrases cuprous oxide cu 2o 17391 2152707 r22 cupric oxide cuo 17380 2152691 r20 r22 iron oxide fe 3o 4 9382 2354425 not applicable. Pentair reserves the right to change specifications without prior notice. Busbar tape key thickness mm cadweld code width mm cadweld code 2ba 20 h 3ca 25 j 3,5 da 30 k 4ea 35 v 5fa 40 l 6pa 50 m 8ga 60 n 10 ha 80 p 100 q ground rods size cadweld code 7 mm p070 10 mm p100 12. The term exothermic means the process gives off heat. Grounding, bonding, and nvent erico cadweld solutions guide.
The cadweld mold part number gives, in code, the complete information of the mold. Use ordinary cadweld molds and get perfect results every time. An xstyle connection can be made by one person in about one minute much faster than other methods. This specification covers the erico cadweld exothermic welding system for. Alt offers exothermic molds that are avaliable in both cadweld and thermoweld. Press and hold operating switch and wait for the ignition open the mould and remove the expended steel cup no special disposal required insert cadweld plus package into mould attach control unit termination clip to. Handle clamp l160 used to securely close the mold around the conductors handle clamps are required for most molds. Type of connection, mold price key, and conductor sizes gtc182v xxxxxxx tad4l3q examples ssc3d vsc2cv3 mold type type ta price key d 750 kcmil. Material safety data sheet cadweld starting material. L160 for all molds having a c, e, r and q mold price key 3 wide molds. They are not clamps, but replace a clamp with a welded connection that thermally fuses the wire to the ground rod find erico cadweld one shot wire to ground rod clamps gt1161v. Handle clamp l160 estimate system resistance values for basic grounding system designs and calculate the number of bags of ground enhancement material required with our gem calculator. Pluscu 165738 cadweld plus control unit with 6 ft 1. The convenient singleuse package makes the connection to the ground rod without a mold or starting material.